The CDI 25 represents a price-performance breakthrough in compressed-air metering. It fills a need for low-cost measurement of air usage by individual pieces of industrial equipment. It indicates leakage and excessive usage locally with blinking lights, thereby eliminating the need for central monitoring and enabling equipment operators and maintenance mechanics to observe and respond to developing problems. $325.
Features
- Low cost permits monitoring of loads throughout an industrial plant
- Alarm functions indicate when leakage has developed or usage has become excessive
- Totalizing function allocates usage and cost
- Complete flowmeter in one package
The CDI 25 is based on CDI’s proven technology, but it has been streamlined to reduce cost, reduce material usage and facilitate installation. The meter measures flow by maintaining one of its two probes warmer than the other; it calculates flow from the amount of heat required. Current flow, as well as minimum, average and totalized flows can be seen on a four-digit display.
Technical Specs
Nominal Pipe Sizes | 1/2 in. - 1 in., DN15 - DN25 |
Accuracy | 5 percent of reading plus 1 percent of range at air temperatures between 20 and 120 degrees Fahrenheit |
Fluids | Compressed Air, Nitrogen |
Operating Pressure | 200 psig maximum |
Input Power | 250 mA at 24 Vdc |
Output Resistance | 600 Ohms max. |
Exposed Materials | Anodized aluminum, aluminum, stainless steel, gold, thermal Stainless steel, aluminum, gold, thermal epoxy and Viton (seal) |
Display | Four digit LED display |
Response Time | One second to 63 percent of change in value at flows above 30 percent of range. |